DLM250
Features
(Click on image to get 200% full page photo)
Click to download DLM200 series Release Notes
in MS Word Format
LEDS:
The DLM250 has tristate Light
Emitting Diodes on the 9 most common interface lines: Transmitted Data,
Received Data, Request to Send, Clear to Send, Data Terminal Ready, Transmit
Clock, and Receive Clock
Line Speeds:
75-57.6k bps Asynchronous, 75-64 kbps Synchronous,
External
NOTE: 115.2KBPS available on DLM350 (includes 2x processor)
Protocols:
Asynchronous, Bisynchronous, SDLC/HDLC, Isochronous
Included accessories:
The DLM200 package includes all you need to begin
monitoring and testing:
A 2 compartment carrying case, wall transformer, batteries,
102 LED Break out Box (BOB100), 9 pin to 25 pin adapters, manual plus quick
start instructions.
Autoconfigure:
Within 20 characters received, determines protocol,
bit rates, number of bits per character, sync character, parity and then
automatically sets the proper parameters and presents captured data to
the screen
Bit/Block Transmission Tests:
Output any of the following strings: RD/TD buffer
FOX All bits user string1/2 FOX2 00, FF Patterns 511 ASCII set 0-FF
Buffer Capacity:
256K bytes of non-volatile RAM for transmitted data
and received data
Historical Data:
Saves/displays state of the modem control lines with
each byte posted to the capture buffer
Triggers:
Triggers can be set to start or stop data capture
on user-defined strings of up to 80 bytes or on interface signal pattern.
Start triggers can be automatically reset after occurrence of stop trigger
by DLM250
Physical (Handheld):
9.25 x 5.50 x 1.37 inches; 23 ounces 23.5 x 13.5 x
3.3 centimeters; 630 grams
Keyboard:
Full 64 key QWERTY keyboard PLUS PC style directional
keypad
Display:
8 line by 30/40 character super twist Liquid Crystal
Display
Response Analysis:
Average times between triggers to the millisecond
(up to four hours) to measure human, computer and communications line performance
Performance:
Analysis BERT performance statistics and performance
calculations.
Help:
Online printable help for all functions
Interfaces:
RS-232. (RS422, V.35 optional)
Parity:
Odd, Even, None
Codes:
ASCII, EBCDIC, BAUDOT, IPARS
Power:
9-volt battery ( 9 hours with alkaline) or by supplied
external transformer
Click here to receive more information
Download DLM250 Brochure (.PDF)
Click to go to BENEDICT COMPUTER
Homepage of hand held RS232 / RS422 MONITORS
& Test Equipment